TBS - Products for Tissue Processing

The SHUR/Wave

SAME DAY DIAGNOSIS
UNCOMPROMISED RESULTS

Witness the latest step in the evolution of
Laboratory Microwave Technology

Download a Brochure
Download the Manual


Laboratory Microwave

The SHUR/Wave™ Laboratory Microwave is the newest addition to the TBS line of quality instrumentation. Specifically designed for fixation and processing of tissue samples, the SHUR/Wave™ can also be used for specimen stabilization and hardening, performing epitope retrieval and accelerating decalcification and staining. It has numerous built-in safety devices that protect the operator, specimen and instrument. It is also extremely user friendly, and even provides prompts that minimize operator error. The SHUR/Wave™ has a Programmable Logic Controller (PLC) that allows at least 30 programs, each with up to 12 steps, to be optimized, stored and run. The Proportional, Integral, Differential (PID) Controller monitors the temperature and works in conjunction with the PLC to assure that the production of microwaves is proportioned to maintain the temperature within your guidelines.

Biopsy specimens can be fixed in 10 minutes and processed in 15 minutes.

Larger specimens require only 55 minutes for complete fixation and 48 minutes to 2 hours for processing, depending on the thickness of the specimen.

Routine specimens can be rapidly fixed to provide the necessary protection before processing or when lymph node detection is important during gross dissection.

Decalcification of bone marrow biopsies can be done in as little as 3 to 10 minutes, depending on the choice of solution. Decalcification time for large specimens can be dramatically reduced by hours or days.

  • Maintain uncompromised morphology and antigenicity
  • Save on exposure, use and disposal of reagents
  • Obtain superior sectioning characteristics
  • Dramatically reduce processing time
  • Lower operating costs
   
 

The SHUR/Wave™ has been tested by a registered independent body to rigorous international quality and safety standards, and has been found to be in compliance with the following regulations and specifications:

UL     61010A
CSA  1010-1
CE    

EN/IEC EN61010-1, Safety
EN61000-3-2, Harmonic Distortion
EN55011, Emissions
EN61326, Immunity

EN61000-3-3, Voltage Fluctuation/Flicker

 